BWT-VENTKIT-Y100
$85.00 NZD
All prices include GST
A 100mm DWV vent kit for your water tank overflow, and the inlet too if you order a second kit. It vents the pipe so a large downpour can't create a siphon that sucks the tank in. Includes a 100mm DWV M/F Y junction with mosquito mesh, a vent cowl and a 100mm tank seal.
Big Water Tanks offers an overflow connection kit to connect our water tanks with ease and simplicity. The vent stops the tank getting "sucked in" when a large downpour runs through the overflow and creates a siphon effect.
The mosquito mesh (gutter foam) is glued into the male top of the Y junction, under the vent cowl. Keep the vent cowl and mesh clear of leaves and debris so air can get into the pipe and the siphon break keeps working.
Each kit includes:
The Y junction may differ from the picture: the mesh is normally glued directly into the male top of the Y, so no separate vent pipe is needed.

This kit can be installed on both the inlet and the overflow for best results. That means 2 kits are generally required, because the overflow needs to be the same size as the inlet or larger.
See our water tanks and the Rain Harvesting range for the rest of your system.
The Y junction connects to the tank through the 100mm tank seal. Water flows through the main run of the Y, and the vent cowl sits directly on the male top of the Y, over the mosquito mesh glued into it. Because the top is open to air, a large flow through the overflow can't pull a vacuum on the tank, so it won't be "sucked in" by a siphon effect. The mosquito mesh keeps insects out of the open vent.

1Pick the height
Mark the hole not too high up the tank: the tank can only fill to the height of the manhole access.
2Drill the tank
Cut the hole with a 127mm hole saw.
3Fit the tank seal
Place the 100mm tank seal in the hole with some lubricant.
4Connect the pipe
Push a nicely cut, de-burred piece of 100mm DWV pipe (not included) into the seal, and connect it to the Y junction.
5Fit the vent
Fit the vent cowl directly onto the male top of the Y junction, over the mosquito mesh, and run your stormwater from the bottom.
Seal fitting steps from our Rubber Tank Seals page.
| Item | Detail |
|---|---|
| SKU | BWT-VENTKIT-Y100 |
| Pipe size | 100mm DWV |
| Pipe outside diameter (seal) | 110.0 - 110.4mm |
| Hole saw size | 127mm |
| Y junction | 100mm DWV M/F, mosquito mesh (gutter foam) glued into the male top |
| Separate vent pipe | Not needed |
| Kits generally needed | 2 (inlet and overflow) |
Seal pipe diameter and hole size from our 100mm BWT tank seal (SEAL-RUBBER100) listing.
We recommend it for tanks of 3000L and larger. For 2000L and smaller tanks, use rubber tank seals to go straight into the tank, or a Rain Harvesting Downpipe Diverter Round or Quickfit Diverter Round.
Without a vent, a large downpour running through the overflow can create a siphon effect that sucks the tank in. The vent cowl lets air in to stop that.
Generally 2: one for the inlet and one for the overflow, as the overflow needs to be the same size as the inlet or larger.
127mm, using a hole saw. Keep it not too high up the tank, as the tank can only fill to the height of the manhole access.
No. We normally supply a DWV M/F Y junction with the mosquito mesh glued directly into the Y, so no separate vent pipe is needed. The Y junction may differ from the picture.
100mm DWV pipe. Our 100mm tank seal suits pipe with an outside diameter of 110.0 - 110.4mm.
yes all good , no worries , friendly delivery man, good tank & fittings , would recommend
Great product tidy easy install